Goodman 2 Ton 14.3 SEER2 Multi-Family Condenser GLXS4MA241
R32 Refrigerant
Standard Features
. High-Efficiency Scroll Compressor
. Factory-installed filter drier
. Fully charged for 15? of tubing length
. 5mm diameter copper tube/enhanced aluminum fin coil
. Service valves with sweat connections and easy-to-access gauge ports
. Enclosed contactor
. Ground lug connection
. Capacitors with extended life
. High-pressure switch
. AHRI Certified
. ETL Listed
Cabinet Features
. Removable grille style top style grill design compatible with UL 60335-2-40
. Heavy-gauge galvanized-steel cabinet
. Venturi for increased velocity of airflow
. Attractive Architectural Gray powder-paint finish with 500-hour salt-spray approval
. Steel louver coil guard
. Single-panel access to controls with space provided for field-installed accessories
. When properly anchored, meets the 2023 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.)
R32 Refrigerant
Standard Features
. High-Efficiency Scroll Compressor
. Factory-installed filter drier
. Fully charged for 15? of tubing length
. 5mm diameter copper tube/enhanced aluminum fin coil
. Service valves with sweat connections and easy-to-access gauge ports
. Enclosed contactor
. Ground lug connection
. Capacitors with extended life
. High-pressure switch
. AHRI Certified
. ETL Listed
Cabinet Features
. Removable grille style top style grill design compatible with UL 60335-2-40
. Heavy-gauge galvanized-steel cabinet
. Venturi for increased velocity of airflow
. Attractive Architectural Gray powder-paint finish with 500-hour salt-spray approval
. Steel louver coil guard
. Single-panel access to controls with space provided for field-installed accessories
. When properly anchored, meets the 2023 Florida Building Code unit integrity requirements for hurricane-type winds (Anchor bracket kits available.)
Click On Links Below For Technical Specifications & Manuals:
GLXS4M Technical Specifications
GLXS,GLZS Warranty Certificate
SEER2 Explained
"SEER2"stands for Seasonal Energy Efficiency Ratio 2. Specifically, SEER2 is the total heat removed from the conditioned space during the annual cooling season. The M1 testing procedure will increase systems' external static pressure by a factor of five to better reflect field conditions of install equipment. With this change, new nomenclature will be used to denote M1 ratings (including EER2 and HSPF2).

"SEER2"stands for Seasonal Energy Efficiency Ratio 2. Specifically, SEER2 is the total heat removed from the conditioned space during the annual cooling season. The M1 testing procedure will increase systems' external static pressure by a factor of five to better reflect field conditions of install equipment. With this change, new nomenclature will be used to denote M1 ratings (including EER2 and HSPF2).